1111 Lockheed Martin Way, Bldg 157 (LMSSC Building 157) is a ~700,000 sq ft industrial manufacturing, office, and laboratory complex operated by Lockheed Martin Space Systems in Sunnyvale, CA. The site supports aerospace defense manufacturing, R&D, and advanced systems integration, with substantial continuous energy loads across multiple floors.

Aerial view of the SUNNYVALE SolarPorts installation
Site aerial
System layout — solar carports and rooftop arrays at SUNNYVALE
System layout — solar carports and rooftop arrays

Projected savings.

Year 1

$215,000

Lifetime (~30 yr)

$16,033,000

By the numbers.

1.1

Years to payback

$38.0M

Total benefits (lifetime)

$22.0M

Property value gain

$677,401

Tax incentives captured

Levelized cost of energy

$0.02 / kWh · SolarPorts
vs.
$1.16 / kWh · PG&E

Like most SUNNYVALE businesses, the site was paying high Peak rates and large Demand charges — the kind of bill structure that punishes daytime energy use and penalizes the very hours commercial properties consume the most power. The result was a Levelized Cost Of Energy (LCOE) of $1.16/kWh from PG&E, reduced to $0.02/kWh from SolarPorts.

SolarPorts evaluated their interval power usage (every 15 minutes) and proposed a right-sized 244 kW solar system for on-site generation delivered as 4 SolarPort carport structures above the parking lot and a rooftop array on the building.

The system now produces roughly 459,835 AC kWh of clean energy each year, an estimated $215,000 in year-one utility offsets, and around $16,033,000 in net lifetime savings — turning a recurring operating-cost into a long-term, predictable energy hedge.

System spec

System design

Site
1111 LOCKHEED MARTIN WAY BLDG 157
SUNNYVALE, CA 94089-1212
APN
11001026
Utility
PG&E
Seismic rating
1.2
Irradiance
2
System size
243.8 kW DC
Estimated production
459,835 AC kWh / year
Year-1 utility offset
$215,000
Lifetime savings (~30 yr)
$16,033,000
Solar panels
390 × Q.TRON XL-G2.3/BFG
(240 carport · 150 rooftop)
SolarPort structures
4
Wire loss
2.0%

Want a system like this on your site?

Free, no-obligation property report — we model your site end-to-end before you sign anything.

Quick request

Prefer email? We'll do the rest.

Fill in the basics and we'll reply within one business day with a model tailored to your site — production, ITC, MACRS, SGIP and demand-charge offset.

Or send us your details and we'll reach out.